Приказ основних података о документу

dc.creatorMicić, Milutin
dc.creatorAntonijević, Đorđe
dc.creatorMilutinović-Smiljanić, Sanja
dc.creatorTrisić, Dijana
dc.creatorColović, Božana
dc.creatorKosanović, Dejana
dc.creatorProkić, Bogomir
dc.creatorVasić, Jugoslav
dc.creatorZivković, Slavoljub
dc.creatorMilašin, Jelena
dc.creatorDanilović, Vesna
dc.creatorĐurić, Marija
dc.creatorJokanović, Vukoman
dc.date.accessioned2023-09-13T12:27:09Z
dc.date.available2023-09-13T12:27:09Z
dc.date.issued2020
dc.identifier.issn0013-5585
dc.identifier.urihttp://intor.torlakinstitut.com/handle/123456789/661
dc.description.abstractFigure 1S. Change of the Ca concentration in the solution containing investigated nHAP granules with time. Figure 2S. Change of the Ca concentration with time in biological apatite (BioOss). Figure 3S. The correlation of the ALBO-OS compressive strenght and the time of the material’s soaking in Hank’s solution. Table 1S. Reference point indentation outcomes of the ALBOOS. MH – microhardness, ID 1st - 1st Cycle Indentation Distance; US 1st - 1st Cycle Unloading Slope; CID 1st -1st Cycle Creep Indentation Distance; TID - Total Indentation Distance; IDI - Indentation Distance Increase; Avg CID - Avg Creep Indentation Distance; Avg US - Average Unloading Slope; Avg US - Average Unloading Slope; Avg LS - Average Loading Slope; Avg ED - Average Energy Dissipated. Table 2S. Ph of nHAP after soaking in simulated body fluid. Figure 4S. Microacrhitectural and structural characteristics of nHAP in vitro and in contact with bone tissue in vivo. Adequate microstructure and surface nanotopography provide good environment for cells infiltration in vivo. Note the presence of porous paterns within material structure in vivo as well as the lamellar structure of ALBO-OS. Figure 5S. Schematic representation of the extruder design in custom made laboratory 3D printer: from technical reasons, 3D printer was modified to include two extruders: 1 – syringe extruder, 1.1 – glass syringe, 1.2 – external frame of the extruder 1, 1.3 – electrical heater coil, 1.4 –metal piston of the syringe, 1.5 – syringe nozzle (0,8mm in diameter), 1.6 – gears of the piston drive, 1.7 – piston drive motor with reduction, 1.8 – HAP PLA mixture, 2 – PLA extruder, 2.1 – heater block of the PLA extruder, 2.2 – extruder cooler, 2.3 – PLA extruder motor drive with reduction, 2.4 – PLA filament 1.75mm in diameter, 2.5 – PLA extruder nozzle 0,4mm in diameter. Figure 6S. Paste extruder attached to the head of the printer, with removed electrical heater coil, so the syringe with the metal piston can be visible. A) The engineered construct used for the experiments and B) its structure after magnification (X200). C-E) Wettability of the construct. Administration of the reference liquid droplet on the construct surface. F) Histogram showing the time required for reference liquid to completely wet the construct surface. Note that the droplet is absorbed within the part of the second.en
dc.publisherWalter De Gruyter Gmbh, Berlin
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172026/RS//
dc.relationinfo:eu-repo/grantAgreement/MESTD/Integrated and Interdisciplinary Research (IIR or III)/45005/RS//
dc.relation.isreferencedbyhttps://intor.torlakinstitut.com/handle/123456789/660
dc.relation.isreferencedbyhttps://intor.torlakinstitut.com/handle/123456789/542
dc.relation.isreferencedbyhttps://doi.org/10.1515/bmt-2019-0218
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceBiomedical Engineering-Biomedizinische Technik
dc.subject3D printingen
dc.subjectbone reconstructionen
dc.subjectpersonalized medicineen
dc.subjecttissue engineeringen
dc.titleSupplementary information for the article: Micić, M.; Antonijević, Đ.; Milutinović-Smiljanić, S.; Trisić, D.; Colović, B.; Kosanović, D.; Prokić, B.; Vasić, J.; Zivković, S.; Milašin, J.; Danilović, V.; Đurić, M.; Jokanović, V. Developing a Novel Resorptive Hydroxyapatite-Based Bone Substitute for over-Critical Size Defect Reconstruction: Physicochemical and Biological Characterization and Proof of Concept in Segmental Rabbit’s Ulna Reconstruction. Biomedical Engineering-Biomedizinische Technik 2020, 65 (4), 491–505. https://doi.org/10.1515/bmt-2019-0218.en
dc.typedataset
dc.rights.licenseBY
dc.description.otherSupplementary material for: [https://doi.org/10.1515/bmt-2019-0218]
dc.description.otherRelated to the published version: [https://intor.torlakinstitut.com/handle/123456789/542]
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_intor_661
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу